How it works

Planning Backup Water in a New Build or Renovation

By the WaterQuotes team · Published 2026-11-13 · 7 min read

Flat illustration of a house floor plan with a tank position, pipe routes and valve locations marked during the building phase

Retrofitting a backup water system to a finished home is entirely possible — but it is rarely cheap or tidy. Trenching through new paving, core-drilling through freshly plastered walls, and chasing conduit into tiled floors are all jobs that cost far more than simply planning for them during the build or renovation. This guide walks through what to decide, and when, so you are not undoing good work later.

Why the timing matters so much

The cost gap between provision and retrofit is almost entirely about access. While a building is under construction, a plumber can lay a 50 mm sleeve through a foundation wall in a few minutes. Once that wall is backfilled, rendered and painted, the same sleeve means breaking out concrete and making good afterwards. The same logic applies to electrical conduit for a pump, a stormwater connection for tank overflow, and the platform or slab a tank will sit on.

There is also a planning advantage. When you can see the pipe routes on a drawing, it is much easier to think through how municipal water and tank water will interact — particularly which circuits or fixtures you want on backup supply and which you do not need to cover. Getting this right on paper is simpler than redesigning around finished cabinetry.

Choosing the tank position early

Tank position drives almost every other decision. Useful questions to work through with your architect or builder:

  • Gravity versus pump-fed. A tank elevated above the house or on a tower can gravity-feed fixtures without a pump, but elevated tanks require a stronger, more expensive base and are more visible. Ground-level or below-ground tanks nearly always need a pressure pump.
  • Distance from the connection point. Every metre of pipe between the tank and the house adds friction loss and cost. A tank tucked behind a garage is often a good compromise between aesthetics and pipe run length.
  • Sun and shade. Tanks exposed to full sun can encourage algae growth and degrade some tank materials faster. A shaded position on the south or east side of a structure is generally preferable.
  • Overflow route. Tanks overflow when it rains heavily or when a float valve sticks. The overflow outlet needs somewhere to drain that will not erode your garden or flood a neighbour — plan this before the landscaping goes in.
  • Access for maintenance. Tanks need occasional inspection and cleaning. Leave enough clearance around the tank for a person to work and, eventually, for a pump to be lifted out.

Once position is agreed, pour a concrete slab or platform at that stage of the build. A correctly sized, level slab is a minor line item in a building budget; having one poured after landscaping is complete is a nuisance job.

Pipe routes and sleeves to rough in

The pipes you need to think about at build stage fall into three groups:

Inlet pipes bring water into the tank — typically from a rainwater downpipe (with a first-flush diverter), a municipal top-up line, or a borehole feed. Each source needs its own connection point and, ideally, its own isolation valve. Sleeve any pipes that cross through foundations or under paving at this stage.

Outlet pipes carry water from the tank to the house. The main line from tank to pressure pump to house should be sized generously — undersized pipes are a common cause of poor pressure performance. Run the outlet pipe through any foundation walls while they are still accessible.

Overflow and drainage needs at least one 50 mm pipe from the top of the tank position to a suitable drainage point. If you are planning a rainwater harvesting component, the overflow often connects to a soakaway or stormwater drain.

For any pipe that passes under a driveway or paved area, lay a sleeve (a larger-diameter pipe you can pull new pipes through later) rather than the pipe itself. This gives you flexibility to change pipe sizes or add extra runs without digging.

Electrical provision

Backup tank systems almost always include a pressure pump, and many include level sensors, solenoid valves for automatic municipal top-up, or a UV steriliser. All of these need power. While walls are open:

  • Run a 20 mm conduit from the main distribution board (or a suitable sub-board) to the tank position. Even if you are not installing a pump immediately, an empty conduit costs almost nothing and saves a great deal later.
  • If you plan to run your backup system off an inverter or solar circuit during load shedding, tell your electrician now — the wiring and circuit protection requirements are different from a standard mains circuit.
  • Decide where the control panel or timer for the system will sit. A position near the main board, under cover, is usually most practical.

For a whole-house backup setup — where tank water is switched in to supply the entire house — the changeover arrangement (whether manual or automatic) needs to be designed into the plumbing from the start. The article on connecting a backup tank to your whole house explains the valve and pipe configuration in detail; reading it before your plumber draws up the plans will save revision costs.

Valves and switching arrangements

The point where tank water meets municipal water is where most of the design complexity sits. At a minimum you need:

  • A non-return valve on the municipal supply line, to prevent tank water from back-feeding into the municipal network (this is a regulatory requirement, not optional).
  • An isolation valve on the tank outlet, so the tank can be taken offline for cleaning or maintenance without interrupting municipal supply.
  • A changeover or selector valve, either manual or automatic, that determines which source is feeding the house at any given time.

If you are building a new home, consider specifying that this valve cluster is located in an accessible, lockable valve box — not buried in a wall or under paving. Future owners (or future you) will be grateful.

For more on how backup systems fit into the broader category of water resilience solutions, the backup water systems pillar page covers the full range of options from small top-up tanks to whole-property setups.

If you are at the design stage and want to know what a properly specified system will cost before you brief your builder, get three free installer quotes — vetted local contractors, no obligation.

Rainwater harvesting: plan the roof and gutters too

If your backup system will include rainwater collection, the roof design matters. A larger effective catchment area (roof plan area, not actual roof area) means more water captured per millimetre of rainfall. Gutters need to be sized for the peak flow from your roof sections, and each downpipe feeding the tank needs a first-flush diverter — a small device that discards the first, most contaminated runoff before directing cleaner water to the tank.

Specify these diverters on the drawing set so your plumber knows where they go and can allow for the extra height they add. A diverter that is retrofitted after the gutters are installed is often awkward to access.

If you intend to use harvested rainwater for drinking or cooking, water quality testing and treatment will be needed to meet SANS 241, the South African drinking-water quality standard. Plan space for a treatment unit (typically a sediment filter plus UV steriliser at minimum) between the tank and the house.

Timing your provision within the build programme

A rough sequence that works in most builds:

  1. At slab or foundation stage: sleeve any pipes that cross foundations; pour the tank platform.
  2. At frame and roof stage: install gutters and downpipes sized for rainwater harvesting; run electrical conduit to tank position.
  3. At plumbing rough-in stage: lay all pipe runs between tank position and house, install the valve cluster, and confirm the overflow route.
  4. At fit-out stage: install the tank, pump and any treatment equipment; commission and test before occupation.
  5. At landscaping stage: nothing left to do except confirm the overflow drains correctly.

If you are renovating rather than building from scratch, the sequence compresses — but the principle is the same: do the invasive work (trenching, core-drilling, breaking out) in a single phase, not across multiple visits.

Planning when to start is also worth some thought. The article on when to install before peak demand covers how installer availability and material lead times shift through the year — worth reading before you lock in a programme with your contractor.

Ready to get real numbers for your project before the walls close up? Compare quotes from up to three installers — WaterQuotes matches you with vetted contractors and you choose who to work with.

What to give your plumber before they quote

The more information you give a plumber upfront, the more accurate their quote will be. A one-page brief with the following is usually enough:

  • Approximate tank size and type you are considering (or ask them to recommend)
  • Tank position relative to the house and the main distribution board
  • Whether you want whole-house supply or only selected circuits
  • Power source (mains, inverter, or both)
  • Whether rainwater harvesting is included, and the roof area that will feed the tank
  • Any water quality requirements (drinking water versus irrigation only)

Bringing this to a quote conversation — rather than starting from a blank page — typically results in faster, more comparable quotes and fewer surprises when the invoice arrives.

Quick answers

Can I add a backup water tank to a house that is already built?

Yes, retrofitting is very common and entirely achievable. The main cost difference compared to planning during construction is access — pipes may need to run externally along walls rather than through them, and any trenching through paving or driveways adds time and cost. Getting quotes from installers who can inspect the site will give you a realistic picture of what is involved for your specific property.

How big should the tank platform or slab be?

The slab needs to be at least as large as the tank's footprint, level to within a few millimetres, and strong enough to carry the full weight of a tank when it is filled with water — water weighs 1 kg per litre, so a 5,000-litre tank weighs 5 tonnes when full. Your installer or structural engineer can confirm the slab thickness required for your soil conditions, but a 100 mm reinforced concrete slab on a well-compacted base is a common starting point for mid-sized tanks.

Do I need council approval to install a rainwater tank or backup system?

Requirements vary by municipality. Many local authorities do not require approval for a standard rainwater or storage tank below a certain volume, but any connection to the municipal supply network — including a top-up line from the main — typically needs to comply with local by-laws and may require a registered plumber to certify the work. Check with your municipality or ask your installer what approvals apply in your area before starting work.

What is a first-flush diverter and do I really need one?

A first-flush diverter is a simple device fitted to a downpipe that discards the first volume of rainwater runoff — which carries the most dust, bird droppings and other contaminants from the roof — before directing cleaner water to your tank. If you plan to use harvested rainwater for anything other than irrigation, a first-flush diverter significantly reduces the contamination load on your filters and tank. They are inexpensive and much easier to install during the build than afterwards.

Should my backup water system run off solar or mains power?

This depends on why you want backup water. If your primary concern is load shedding cutting the pump during a water outage, connecting the pump to an inverter or solar circuit makes good sense. If your concern is primarily municipal supply interruptions rather than power cuts, a mains-powered pump may be sufficient. Many homeowners opt for a pump that can run on either source, with an automatic transfer switch — your installer can advise on what is practical for your existing or planned electrical setup.

Sources & notes

Pricing reflects typical Johannesburg market ranges and is confirmed by installer quotation. References: SABS

Ready to compare? Get up to 3 quotes from vetted backup water systems installers in Johannesburg — free, no obligation.

Get 3 free quotes